UK Concrete Grades C25, C30 and C35 Explained

Concrete mixer truck pouring fresh concrete for a house foundation on a UK building site

Ordering concrete in the UK means choosing a grade, and the grade you pick decides whether the slab is strong enough, lasts in frost, and passes building control. Pick too low and the surface wears, cracks or flakes. Pick too high and you pay for strength you do not need. For most domestic jobs, C25 suits foundations, shed bases and light slabs, C30 suits driveways, garage floors and exposed slabs, and C35 suits commercial floors, heavy loads and structural work. The C number is the strength in newtons per square millimetre after 28 days, so C25 means 25 N per mm2 and C30 means 30 N per mm2.

The short answer

Start with the job, not the number. A garden path or patio in light use can use C20 or C25. A domestic driveway for cars needs C25 to C30, and C30 if it faces frost or heavy use. Foundations usually need C25, as GEN3, or a higher grade if the design says so. Commercial floors and structural slabs need C30 to C35. Outside in wet, freezing weather, the grade alone is not enough: it must be an air entrained PAV mix, PAV1 for C30 and PAV2 for C35. When in doubt, ask the supplier what the concrete is for, where it sits, and what will drive on it.

What the C number means

The C stands for compressive strength, and the number is the characteristic strength after 28 days of curing. In the UK, testing uses a 150 mm cube cured in lab conditions for 28 days, so C25 means at least 25 N per mm2. You may also see a dual number, such as C25/30. Under BS EN 206, that means 25 N per mm2 on a cylinder and 30 N per mm2 on a cube; UK practice quotes the cube figure, which is why a mix is often called simply C30. A higher number means a stronger, denser mix, usually with more cement and a lower water-cement ratio. It does not mean the concrete sets faster, and it does not on its own make a slab frost proof. Frost resistance comes from air entrainment, not strength alone.

GEN, RC and PAV: the UK map

BS 8500 gives UK buyers two routes. Designated mixes cover the most common jobs with preset requirements for cement type, water-cement ratio and strength. Designed mixes are specified by an engineer for a particular job. The three designations you will meet most are GEN, for general non-structural work, RC, for reinforced concrete, and PAV, for paving and external slabs that face traffic and frost. The table maps them to C grades.

Designation Typical C grade What it is for
GEN1 C10 Blinding, mass fill, non-structural
GEN2 C15 to C20 Light paths, non-structural slabs
GEN3 C25 Domestic foundations, floor slabs
RC25 to RC35 C25 to C35 Reinforced foundations and slabs
PAV1 C30 Driveways, external paving, frost
PAV2 C35 Heavy external paving, commercial yards
FND2 to FND4 Varies Foundations in sulphate ground

GEN3, equivalent to C25, is the standard for domestic foundations, according to Pro Concrete 247. RC35 is a typical commercial structural mix. If your ground has sulphates, the supplier may specify an FND mix instead, so tell them about the ground conditions, not just the job.

Decision table: which grade for which job

Use this table to pick a starting point, then confirm it with the supplier. The grade in the table is the minimum that suits the job in normal conditions. Poor ground, heavy loads or frost exposure all push you one grade higher.

Job Grade to order Notes
Garden path, light patio C20 Foot traffic only
Shed base, garden office C25 GEN3, light building
House foundations, extension C25, GEN3 Check the design first
Garage floor, cars only C25 Step up to C30 for vans
Driveway, cars C25 to C30 C30, PAV1, if exposed to frost
Driveway, vans and trailers C30 to C35 PAV1 or PAV2
External patio, exposed C30, PAV1 Air entrained for frost
Commercial floor, yard C35, PAV2 Engineer specified

C25 vs C30 vs C35 head to head

C25 is the general purpose workhorse, strong enough for footings, ground bearing slabs, driveways under regular car traffic and patios, and economical for a large pour. Find the Needle notes that C25, at 25 N per mm2, bridges light domestic and genuine structural duty. C30 is built for the weather. At 30 N per mm2, it is the first grade made to face the elements, and as PAV1 it is supplied as a designed, air entrained mix. Driveways, hardstanding and exposed patios belong in C30, where an ordinary mix would pit and flake after a few cold seasons. C35 steps into commercial and structural work, suiting commercial floors, heavy duty paving, reinforced and raft foundations, and yards that carry machinery daily. The step from C25 to C30 is a 20 percent rise in strength, but the real gain for a driveway is the frost resistance of the PAV1 mix, not the number alone.

How to order from a UK supplier

Order by designation and job, not by a mix ratio. Say the designation, such as GEN3 or PAV1, the volume, the slump you need, and the delivery date and access. Tell the supplier what the concrete is for, whether it is inside or outside, whether it faces frost, and what will drive on it. Ask about the minimum load, often about 1 cubic metre, since a small order may cost the same as a larger one. Check the ticket when the truck arrives: it should show the grade, designation and slump class. If it does not match, do not pour it. For the US comparison, read our concrete PSI chart.

Nominal mixes and hand mixing

You will see nominal mix ratios quoted for each grade, such as 1:2:4 for C25, 1:2:3 for C30 and 1:1.5:3 for C35. These are rough guides for small hand mixed jobs only, and do not reliably meet the grade. Structural work, reinforced work and any grade from C30 up should be bought as ready-mix to a designated mix, not mixed by guesswork. If you hand mix a small job, use the same bucket for every part and measure the water. Our 1:2:4 mix ratio guide explains that mix, and our slab thickness guide helps you pair grade with thickness.

Mistakes to avoid

  • Ordering by price alone. The cheapest grade is not the right grade for an exposed slab.
  • Using C25 outside without air entrainment. Frost will pit and flake the surface.
  • Guessing a site mix for structural work. Buy ready-mix to a designated mix.
  • Forgetting the ground. Sulphate soil needs an FND mix, so tell the supplier.
  • Adding water on site. It cuts strength whatever grade you ordered.
  • Ordering too little. Check the minimum load and add 5 to 10 percent waste.

Frequently asked questions

What is the best concrete grade for a driveway?

For cars, C25 to C30, and C30 as PAV1 if exposed to frost. For vans, trailers or heavy loads, step up to C35 as PAV2. The PAV mix matters as much as the number.

Is C25 strong enough for foundations?

Yes, for most domestic foundations, as GEN3. Larger buildings, poor ground or a design calling for more strength need a higher grade, so check the design first.

What is the difference between C25 and C30?

C30 is 20 percent stronger, at 30 N per mm2 against 25, and as PAV1 it is air entrained for frost. For a driveway or exposed slab, C30 is the safer upgrade. For a shed base, C25 is usually enough.

What does GEN3 mean?

GEN3 is a BS 8500 designated mix, equivalent to C25, for domestic foundations and floor slabs. GEN mixes are preset by the standard, so the supplier knows the mix without a separate design.

Can I use C35 for everything?

You can, but you will pay more for strength you do not need, and a richer mix can be harder to finish. Match the grade to the job instead.

How do UK grades compare to US PSI?

UK grades use newtons per square millimetre at 28 days, while US grades use pounds per square inch. C25 is about 3,625 PSI and C30 is about 4,350 PSI. Our PSI chart gives the full comparison.

Conclusion

Pick the grade by the job, not by habit. C25 covers most domestic foundations and light slabs. C30, as PAV1, covers driveways and exposed work. C35 covers commercial and structural jobs. Tell the supplier what it is for, order by designation, and check the ticket on arrival. The right grade, a good base and proper curing will outlast a stronger mix poured badly every time.

Sources

Last verified: November 2026.

About the author

Kaleemullah Formulas use standard geometry and published bag yields; sources are linked in each article.

Leave a Comment

Your email address will not be published. Required fields are marked *